Sindie® R1 - Sindie® R2 - Sindie® R3 - Sindie® R4 and Sindie®+Cl

The XOS Sindie® R-series benchtop analyzers are easy to use, allow you to perform rapid tests, to work in compliance with method directives in a flexible, accurate and precise way.
Based on MWDXRF technology, these analyzers provide direct measurements and require no gas consumption or sample handling.

Sindie benchtop analyzers are the ideal solution for the analysis of sulfur at the ultra trace level and are used in the analysis of:

  • Petroleum products (diesel, jet, kerosene, other distillate oil, naphtha, residual oil, lubricating base oil, hydraulic oil, crude oil, gasoline, gasoline-ethanol blend, coal and petroleum cokes)
  • First and second-generation biofuels (biodiesel, ethanol, renewable diesel, HVO, SAF)
  • Oils (edible) and fats (UCO, Tallow, palm oil, corn oil, soybean oil, etc.)
  • Chemicals (toluene, xylene, methanol, benzene etc.)
  • Water.

Sindie R1

Easier to use than ever, Sindie R1 is the ideal sulfur analysis solution to help you stay in compliance with ASTM D2622, ASTM D7039, ISO 20884, and EN 16997 methods, enabling flexibility for your analytical needs at a more affordable price.

Features: 

  • LOD: 0.7 mg/kg (ppm) at 300s, 0.5mg/kg (ppm) at 600s
  • Dynamic range: 0.7 mg/kg (ppm) to 10 wt%
  • Low and high range available:
    • Low range: 0.7 mg/kg (ppm) – 3000 mg/kg (ppm)
    • High range: 0.3 wt% – 10 wt%.

SIindie R2

Easier to use than ever, Sindie R2 provides the best value and combination of detection limits, measurement speed, ease of use and reliability. Sindie R2 is the ideal sulfur analytical solution to help you stay in compliance with ASTM D2622, ASTM D7039, ISO 20884, and EN 16997 methods, enabling complete flexibility for your analytical needs.

Features:

  • LOD: 0.4 mg/kg (ppm) at 300s, 0.28 mg/kg (ppm) at 600s
  • Dynamic range: 0.4 mg/kg (ppm) to 10 wt%
  • Low and high range available:
    • Low range: 0.4 mg/kg (ppm) – 3000 mg/kg (ppm)
    • High range: 0.3 wt% – 10 wt%.

Sindie R3

Easier to use than ever, Sindie R3 is sulfur analytical solution for compliance with ASTM D2622, ASTM D7039, ISO 20884, and EN 16997 methods, enabling complete flexibility for your analytical needs. Advanced R3 optics, provide extremely low limits of detection, allowing for cycle time flexibility to save up to hours per day in testing time.

Features: 

  • LOD: 0.18 mg/kg (ppm) at 300s, 0.15 mg/kg (ppm) at 600s**
  • Dynamic range: 0.18 mg/kg (ppm) to 10 wt%
  • Advanced R3 optics allow for optional lower background measurement time.
  • Low and high range available:
    • Low range: 0.18 mg/kg (ppm) – 3000 mg/kg (ppm)
    • High range: 0.3 wt% – 10 wt%. 

Sindie R4

Easier to use than ever, Sindie R4 is our most advanced sulfur analytical solution for compliance with ASTM D2622, ASTM D7039, and ISO 20884 methods, enabling complete flexibility for your analytical needs. Advanced R4 optics provide extremely low limits of detection and allow for cycle time flexibility to save hours per day in testing time.*

Features:

  • LOD: 0.12 mg/kg (ppm) at 300s, 0.09mg/kg (ppm) at 600s**
  • Range: 0.12 mg/kg (ppm) – 10 wt%
  • Advanced R4 optics allow for optional lower background measurement time and shorter total measurement time
  • Low and high range calibrations available:
    • Low range: 0.12 mg/kg (ppm) – 3000 mg/kg (ppm)
    • High range: 0.3 wt% – 10 wt% .

Sindie ® +Cl is a two-in-one instrument enabling trace analysis of both sulfur and chlorine with one analyzer.
It is the ideal solution to certify sulfur levels in finished products, assess chlorine for corrosion mitigation, and optimize process parameters. *
Compliance with Test Method ASTM D2622, D7039, D7536, D4929 ISO 20884, and SH/T 084.

Features:

  • Sulfur: LOD: 0.4 mg/kg (ppm) at 300s, 0.28 mg/kg (ppm) at 600s*
    • Dynamic Range: 0.4 mg/kg (ppm) to 5 wt%
  • Chlorine: LOD: 0.3 mg/kg (ppm) at 300s, 0.21 mg/kg (ppm) at 600s*
    • Dynamic Range: 0.3 mg/kg (ppm) to 3000 mg/kg (ppm)
  • Automatic sulfur correction saves time and improves accuracy and precision on high sulfur samples.

All Sindie R-series analyzers are:

  • Easy to use: Intuitive 10-inch touch screen - Just plug in and measure - Measurement time: 10-999 s
  • Low maintenance: no gasses, heating elements, columns, or quartz tubing
  • Traditional 43 mm XRF sample cups or XOS Accucells
  • Small footprint
  • LIMS integration for data management and transfer
  • Custom sample presets to save data entry time and minimize data entry error on common samples
  • Bar code reader autofills sample name to reduce data entry time
  • Storage capacity for more than 50,000 measurement results Supports up to 30 calibration curves USB connectivity in front and back for connecting to printer, keyboard, mouse, and memory stick. Supports USB and network printers Large, easy-to-remove side panels for easy serviceability Advanced error reporting and diagnostics.

SRA Instruments S.R.L.

Via alla Castellana, 3
20063 Cernusco sul Naviglio MI

Tel: +39 02.92.14.32.58
Fax: +39 02.92.47.09.01
Email: info@srainstruments.com